How to connect FOX ESS AIO-H3 system (battery, hybrid inverter, energy meter) with Reduxi controller
Connect a FOX ESS AIO-H3 all-in-one system (battery, hybrid inverter, energy meter) to the Reduxi Controller via Modbus.
1 Technical documentation
The FOX ESS AIO-H3 is a three-phase all-in-one energy storage system: hybrid inverter and lithium iron phosphate (LFP) battery in one system. The data below comes from the FOX ESS datasheet.
Manufacturer documents:
- AIO H3 datasheet V3.5 – datasheet (PDF, EN, 2024-11-08)
- FOX ESS downloads – datasheets, manuals and other documents (web, EN)
2 Required equipment
- Reduxi Controller (installed and online)
- FOX ESS AIO-H3 system, commissioned
- Connection between the inverter and the Reduxi Controller (see Point 3)
- Laptop or tablet with internet access to configure the device in Reduxi
3 System overview and wiring
The Reduxi Controller reads the measured values of the AIO-H3 and sends the commands of the Reduxi strategies. Reduxi lists the AIO-H3 with the Modbus protocol in the List of supported devices.
| Interface | Where | Note |
|---|---|---|
| LAN, Wi‑Fi, 4G (optional) | Monitoring module | Network connection of the system |
| 2×RS485 | Inverter | Serial interfaces of the inverter |
| CAN, RS485 | Battery | Communication battery – inverter, BMS upgrade |
| DRM, ripple control, USB | Inverter | Grid operator interfaces and service |
4 Log in to the Reduxi web interface
You can open the Reduxi web interface in two ways:
Text description of this image
Screenshot of three Reduxi mobile app screens side by side, with cyan boxes and number badges 2 to 4. Left screen (dashboard, dark theme): menu icon at top left marked with a box and badge 2; 'reduxi' logo; tabs 'Real time data' (active) and 'Statistics'; price 5.79 € and temperature 3.2 °C; energy flow diagram with a house in the centre (-1.25 kW) and icons with values 69.0 W, 1.3 kW, 1.1 kW (red ring), -165.0 W with 97 % (red ring) and 0.0 W values at the bottom; tabs 'Power' and 'Energy'; bottom navigation: Dashboard, Diagnostics, Device control, Settings. Middle screen (side menu): 'reduxi' logo, 'Number of locations: 1233', heading 'Reduxi device management', entries '+ Add Reduxi location' and 'Reduxi devices' (marked with a box and badge 3), then 'My profile' and 'About app'. Right screen (device page): Back; picture of a black Reduxi controller with two Ethernet ports; status 'Connected'; card 'Update available': 'New update is available for your Reduxi device.' with button 'Download and install update'; card 'Connect to configurator': 'Tunnel connection enables remote access to your Reduxi configurator, without need to be connected to the same local network.' with button 'Activate tunnel connection' (marked with a box and badge 4); card 'Unit details' with field 'Unit ID'.
Text description of this image
Screenshot made of two parts side by side. Left part: Reduxi mobile app screen on a dark background. Top: Back button; picture of a black Reduxi controller with two Ethernet ports and a terminal block; status 'Connected' with a Wi-Fi icon. Card 'Update available': 'New update is available for your Reduxi device.' with button 'Download and install update'. Card 'Connect to configurator' with a key icon: 'Tunnel connection enables remote access to your Reduxi configurator, without need to be connected to the same local network.' and button 'Open configurator', marked with a cyan box and number badge 5. Below: card 'Unit details' with a field 'Unit ID' (value not visible). Right part: Reduxi Configurator opened in a browser, marked with a cyan frame and number badge 6. Header: back arrow, 'Tunnel connection', reload icon. Left sidebar with icons (lightning, chip, lightning bolt, bar chart, gear). Page 'Home' with a green link icon. Green notice: 'New patch available. Click here to apply.' with a close X. Time 09:12:56. Energy flow diagram with a house in the centre (1.700 kW) and icons for grid (0.000 kW), solar (1.700 kW), battery (green, 0.000 kW and 0.800 kW), a device at left (0.900 kW), electric vehicle and a charger or device at bottom. Label 'Energy manager' at the bottom.
http://reduxi.local. You can find the controller's IP address in your router's device list or in the Reduxi app under Reduxi devices.admin · Password: admin (factory default)Text description of this image
Screenshot of the Reduxi Configurator login page in a Chrome browser window. The address bar shows 'Not secure' and 'reduxi.local'; the address bar is marked with a cyan box and an enlarged copy of it (cyan box, text 'Not secure reduxi.local') is shown at the left, connected by a cyan line. Page background: light grey line drawing of a house with solar panels (green), a wall box, an inverter, a car and a charger. Top left: 'reduxi configurator' logo. Login box in the centre with title 'Login', a language selector (English flag, 'English'), a username field and a password field, and a dark 'Login' button.
Text description of this image
Screenshot of the Reduxi Configurator web interface after login, light theme. Top left: 'reduxi configurator' logo. Header bar: 'Home' at left, green 'Connected' status at top right. Left sidebar: expanded section 'Devices' with a list of entries, then collapsed sections 'Manager' and 'Configuration' and 'Settings'. Main area: energy flow diagram. House in the centre with ring, value 24.20 kW. Grid icon at top left, 24.20 kW (red dot on its line). Solar icon at top right, value '-'. Left icon (battery or device), 6.700 kW (green dot on its line). Right icons (battery storage and a device), values '-'. EV charger icon at bottom left, 31.00 kW. A further device icon at bottom right. Label 'Energy manager' below the house.
5 Add the device to Reduxi
Open the Configurator first, see Point 4. The device is added with the wizard in two steps.
5.1 Basic settings
FOX ESS AIO-H3. Tick the strategies the device should take part in, then click Next.The List of supported devices also contains the entry FOX ESS AIO H3 for the energy meter.
5.2 Communication settings
The second step sets up the Modbus communication between the Reduxi Controller and the AIO-H3. Enter the connection type, the address and the Modbus unit ID as they are set on the system.
5.3 Test communication
Click Test communication at the bottom of the wizard. It reads the FOX ESS AIO-H3 once and saves nothing. If the test succeeds, click Done: only Done creates the device.
Text description of this image
Screenshot of the bottom button bar of a Reduxi Configurator page. Left: button 'Back'. Right: button 'Test communication' (marked with a cyan box) and dark button 'Done'.
Text description of this image
Screenshot of the Reduxi Configurator page 'Communication channel and device configuration'. Connection *: TCP/IP (dropdown). IP *: 192.168.50.243, with button 'Scan for IP'. Port *: 502, with button 'Test port'. Modbus unit ID *: 1. Buttons at the bottom: Back (left), Test communication and Done (right). The Done button is marked with a cyan box.
6 Check the readings
6.1 Last measurements
Open Devices → FOX ESS AIO-H3 → Last measurements in the Configurator. The values show whether the system communicates correctly.
6.2 Control behaviour
The List of supported devices shows per device type whether Reduxi reads only or reads and controls. Where control is available, open Devices → FOX ESS AIO-H3 in the Reduxi Configurator and set the control type to AUTO. Only then do strategy commands affect the system.
To reduce energy costs with dynamic prices and tariffs, define the strategy as described in Strategies for Reduxi controller.
✓ Summary
Preparation (Points 1–2): Check the datasheet and prepare the equipment.
FOX ESS AIO-H3 (Point 3): Connect the system to the Reduxi Controller. Reduxi reads it through Modbus.
Add to Reduxi (Points 4–5): Open the Configurator, add a Hybrid inverter of type FOX ESS AIO-H3, enter the communication settings, run Test communication and click Done.
Go live (Point 6): Check the last measurements. Where control is available, set the control type to AUTO.
→ Common issues
| Issue | Solution |
|---|---|
| Test communication fails | Check the connection type, address and Modbus unit ID against the settings on the system. Controller and system must be able to reach each other. |
| The device goes offline after some time | Check that the connection settings of the system did not change, for example the IP address after a router restart. |
| Open configurator does not open or stays empty | The tunnel is not active yet. Wait about 30 seconds and check that the controller is online. |
Login with admin is rejected |
The password was changed during installation. Ask the installer. The Reduxi account password does not work here. |
reduxi.local does not load |
Your device is not in the same network as the controller. Use the IP address or the tunnel connection. |