1 Overview
The Reduxi Controller and P1 Ultra converters talk to meters, inverters, batteries, EV chargers and heat pumps over a range of physical interfaces and protocols. This page lists what is supported today and what is on the roadmap. Where a protocol has its own article, it is linked directly in the tables below.
2 Interfaces by device
Which physical interfaces are built into each Reduxi device, including the Reduxi Gateway as system extension. Interfaces a device doesn't have can often be added with a Reduxi Converter, the Reduxi Gateway or an external Shelly Pro device.
| Interface | Controller / DIN | Controller Industrial | P1 Ultra Plus | P1 Ultra Pro | Gateway |
|---|---|---|---|---|---|
| Ethernet (RJ45) | 2×1 Gbps WAN + 100 Mbps LAN | 2×1 Gbps WAN + 1 Gbps LAN | — | — | 1×10/100 Mbps |
| Wi‑Fi | ✓2.4 / 5 GHz | ✓internal antenna | ✓ | ✓ | ✓2.4 / 5 GHz |
| Mobile (4G/LTE) | ✓PRO version, external antenna | ✓external antenna | — | ✓SIM slot, external antenna | — |
| RS485 | 1×more via Gateway | 2× | 1×for additional devices | 1×for additional devices | 1× |
| Digital inputs | —via Gateway / Shelly Pro | 6× | — | — | — |
| Relay outputs | —via Gateway / Shelly Pro | 4× | — | — | 2× |
| Current‑transformer inputs | —via Gateway | — | — | — | 3× |
| M‑Bus (wired) | —via Converter | ✓1× master + 1× slave | ✓2‑wire, RJ12 or RJ45 | ✓2‑wire, RJ12 or RJ45 | — |
| CAN | —via Controller Industrial | 1×2× version available | — | — | — |
| P1 / HAN / I1 (TTL) | —via P1 Ultra / Converter | —via P1 Ultra / Converter | ✓RJ12 | ✓RJ12 | — |
| Power supply | 5 VUSB‑C adapter / DIN‑rail PSU | 24 V DC | see device article | 12–24 V DC | |
| Documentation | Setup guide | Technical manual | P1 Ultra Plus / Pro guide | Gateway manual | |
3 Physical interfaces
The physical layer defines how a device is wired or connected. For which device has which interface, see Interfaces by device.
Available supported today · Coming soon on the roadmap · Via add‑on needs an external device
| Interface | Status | Typical use & related article |
|---|---|---|
| Ethernet (LAN/WAN) | Available | Internet connection and local network devices (Modbus TCP, REST, OCPP) · Reduxi Controller 2.0 Network settings |
| Wi‑Fi | Available | Wireless connection to the local network; P1 Ultra Plus / Pro send meter data via Wi‑Fi · Network settings |
| Mobile (4G/LTE) | Available | Mobile internet where no LAN or Wi‑Fi is available – Reduxi Controller PRO, Controller Industrial and P1 Ultra Pro · P1 Ultra Pro LTE setup |
| RS485 (EIA‑485) | Available | Wired serial bus for Modbus RTU devices such as meters and inverters · Wiring, cable types and connection diagram |
| Digital inputs / relay outputs |
Available Via add‑on |
Switching contacts, e.g. EVU/SG Ready for heat pumps. Built into the Controller Industrial (6× digital inputs, 4× relays); for the Reduxi Controller / DIN via the Reduxi Gateway or a Shelly Pro · Connect any heat pump via EVU contact |
| M‑Bus (wired) | Available | Meters with M‑Bus interface – built into Controller Industrial and P1 Ultra Plus / Pro · P1 Ultra Plus / Pro with energy meter |
| P1 / HAN / I1 (TTL) | Available | Smart meter customer interface via P1 Ultra Plus / Pro · P1 Ultra Plus / Pro with energy meter |
| CAN | Available | Via the Controller Industrial (1× CAN, 2× CAN version available) · No article yet |
4 Communication protocols
The communication layer defines the "language" the controller and the device speak over the physical connection.
Fieldbus & meter protocols
| Protocol | Status | Typical use & related article |
|---|---|---|
| Modbus (RTU) | Available | Inverters, meters and batteries over RS485 · Connecting devices to Reduxi Controller · Modbus slave connector |
| Modbus TCP | Available | Network devices over LAN/Wi‑Fi · Example: KEBA KeContact P30 via Modbus TCP |
| DLMS | Available | Smart grid meters · Telegram structure for Iskraemeco AM550 |
| DLMS push | Available | Meters that push data cyclically via the customer interface · Telegram structure for Landis+Gyr E350/E450 |
| M‑Bus (EN 13757‑2) | Available | Meters with M‑Bus interface · P1 Ultra Plus / Pro with energy meter |
| CAN | Available | Via the Controller Industrial · No article yet |
| eBus | Coming soon | No article yet |
Network, cloud & integration protocols
| Protocol | Status | Typical use & related article |
|---|---|---|
| OCPP 1.6 | Available | EV charging stations · Connect an EV charging station over OCPP 1.6 |
| OCPP 2.0.1 | Coming soon | No article yet |
| REST API | Available | Devices with an HTTP interface · Example: sonnenBatterie (REST API) |
| MQTT | Available | Integration with brokers and third‑party systems · Reduxi Controller MQTT API · Example: connect to an MQTT broker |
| EEBus | Available | EEBus‑compatible heat pumps and wallboxes · Add EEBUS compatible device |
Grid & utility protocols
| Protocol | Status | Typical use & related article |
|---|---|---|
| IEC 60870‑5‑104 (IEC‑104) | Available | Telecontrol communication with grid operators and plant control systems · No article yet |
| IEEE 2030.5 | Coming soon | No article yet |
5 Reduxi Converters
Reduxi Converters translate additional interfaces to RS485, so devices that don't speak one of the controller's native interfaces can still be integrated.
| Conversion | Status | Typical use & related article |
|---|---|---|
| M‑Bus (EN 13757‑2) → RS485 | Available | Meters with M‑Bus interface · Release notes – Reduxi Converter and Gateway |
| TTL → RS485 | Available | Smart meter customer interfaces (e.g. P1 port) · Reduxi Converter for Iskraemeco AM550 · P1 WiFi / Ultra in the Reduxi Configurator |
| EMS‑Bus → RS485 | Available | Heating systems with EMS‑Bus · No article yet |
| eBus → RS485 | Coming soon | No article yet |
→ Summary
- Reduxi Controller / DIN: 2× Ethernet, Wi‑Fi, 1× RS485; LTE on the PRO version.
- Controller Industrial: 2× Ethernet, Wi‑Fi, LTE, 2× RS485, 6× digital inputs, 4× relays, M‑Bus master/slave and CAN.
- P1 Ultra Plus / Pro: P1/HAN/I1, M‑Bus and RS485 towards the meter, Wi‑Fi towards Controller or Cloud; the Pro adds LTE.
- Most common device protocols: Modbus RTU/TCP, DLMS/DLMS push, M‑Bus, OCPP 1.6, REST API, MQTT and EEBus.
- Grid integration: IEC‑104 is supported; IEEE 2030.5 is coming soon. CAN is available via the Controller Industrial.
- Extending the system: the Reduxi Gateway adds 1× RS485, 2× relay outputs and 3× current‑transformer inputs.
- More protocols: Reduxi Converters add M‑Bus, TTL and EMS‑Bus (eBus coming soon) via RS485.
→ Common issues
| Issue | What to do |
|---|---|
| My device's protocol or model isn't listed | Check the List of supported devices first. If it's still missing, see Can we add a device to the list of supported devices? |
| Modbus TCP / network device can't be reached | Make sure the device is in the same network and check its IP address · Test if an ethernet device is reachable · Find an automatically assigned IP address (DHCP) |
| No data from an RS485 device | Check A/B polarity, cable type and bus termination · Wiring, cable types and connection diagram |
| Need a "coming soon" protocol for a project | Contact Reduxi Support with your project details so we can check the current roadmap status. |