Checklist: planning and prerequisites for a Reduxi installation
Everything you clarify and bring before the installation appointment: devices, measurement point, material, space and network.
1 Why plan before the appointment
A good installation starts before the mounting. Use this checklist before every appointment. It follows module 2 “Planning and prerequisites” of the Reduxi installer certification program.
2 Clarify the devices in advance
Create a list of all devices that should be connected: manufacturer, model and location. Then tick off the following points for every device.
- Device list created: manufacturer, model and location
- All devices checked in the list of compatible devices
- Device setup guides read (there is one for many devices)
- Communication active on every device:
Modbus TCP,Modbus RTUorOCPP - Access data and manufacturer app available: account, password, installer access or service code
- Connection data noted: IP address and port; for Modbus RTU the connection type, baud rate, data bits, stop bits and parity
3 Measurement at the grid connection point
Reduxi needs a measurement at the grid connection point (root measurement). It must capture all power flows. There are three ways:
- Smart meter of the grid operator with the P1 Ultra
- Smart meter with Modbus TCP or Modbus RTU, installed after the grid operator’s meter or in its place
- Smart meter of an inverter, if it sits directly behind the grid operator’s meter
- Root measurement clarified: all power flows are captured
- Measurement variant decided (you decide on site)
- Meters that can only be read via the infrared interface: IR sensor for the P1 Ultra planned
- Key for the customer interface of the grid operator requested: the customer contacts their grid operator in good time
- Fuse values for L1, L2 and L3 noted in the meter cabinet
- Connection power requested from the last electricity bill
4 Material and accessories
Plan the power supplies and accessories when you order:
| Product | Power supply | Note |
|---|---|---|
| Controller stand-alone | 230 V to 5 V, USB-C | Included, ready to plug in |
| Controller DIN rail | DIN rail power supply 5 V | Needs 1 TE next to the controller (4 TE wide) |
| Controller Industrial | DIN rail power supply 24 V | Needs 2 TE |
| Reduxi Gateway | 230 V to USB-C | Included; clarify the current transformer size (15, 30, 50 or 100 A, or without clamps) |
| P1 Ultra Plus / Pro | 230 V to USB-C or DIN rail 5 / 24 V | Not included, order separately |
- Current transformer size for the Gateway clarified: 15, 30, 50 or 100 A, or without clamps
- Matching power supplies ordered (the P1 Ultra comes without one)
- SIM card available if mobile data is used, including PIN and APN (separately available, requests to sales@reduxi.eu)
5 Space and network
Clarify how the controller gets onto the network and whether everything fits in the cabinet.
- Controller including power supply fits into the distribution cabinet (width in TE)
- Location of the controller and cable routes to inverter, battery and meter clarified
- Connection decided: Ethernet, WLAN or mobile data; free port on the router, number of routers known
- WLAN name and password ready (for the P1 Ultra only 2.4 GHz)
- Fixed IP addresses clarified with the customer
- Firewall approvals clarified with IT, if a firewall is in use (see “Reduxi Firewall rules”)
6 What you bring
- Reduxi app and Reduxi Cloud account
- Laptop for the local interface (web interface of the controller)
✓ Summary
Devices (Point 2): List ready, all devices compatible, communication active, access data and app available.
Measurement (Point 3): Root measurement clarified, key for the grid operator’s customer interface requested, fuse values for L1, L2 and L3 noted.
Material (Point 4): Power supplies, current transformer size, SIM card and IR sensor clarified.
Space and network (Points 5–6): Cabinet space, network connection, fixed addresses and firewall clarified; app, account and laptop with you.
→ Common issues
| Issue | Solution |
|---|---|
| The connection test in Reduxi fails | Communication is not active on the device. Switch on Modbus TCP, Modbus RTU or OCPP in the manufacturer’s app or web interface and check the access data. |
| The controller is unreachable after saving network settings | A wrong fixed address was entered. Use a second access (for example the tunnel connection) or search for the controller with a network scanner. |
| The P1 Ultra does not connect to the WLAN | The P1 Ultra only supports 2.4 GHz. Use a 2.4 GHz network. |
| The SIM card is blocked | A wrong PIN was entered. Check PIN and APN with your provider before you insert the card. |