Reduxi Gateway setup in Reduxi Gateway Configurator page
Reduxi Gateway measures with current sensors, switches devices through relay outputs and converts RS485 to TCP/IP.
Text description of this image
Picture of the Reduxi Gateway on a white background, with the label Reduxi Gateway above it. Dark grey box-shaped device; the lid shows the reduxi GATEWAY logo (upside down from the viewer). The front panel has a six-pin terminal block printed with GND, PORT 1 A B, PORT 2 A B, 5V, and three round sockets labelled I1, I2 and I3. Black cables from three blue clamp-style current sensors are plugged into the I1, I2 and I3 sockets; the cables are coiled in front of the device.
1 Reduxi Gateway introduction
Reduxi Gateway has three uses:
- A measurement device with current sensors.
- A controllable device to connect Smart Grid contacts or similar.
- A basic gateway that converts the RS485 signal to TCP/IP.
Reduxi Gateway is an add-on device to the Reduxi Controller, which is the primary logic unit. It offers two RS485 ports, three inputs for current sensors and two relay outputs. You connect it to the local area network with an Ethernet cable or via Wi‑Fi.
RS485 to TCP/IP. With this conversion, old devices that do not support TCP/IP become accessible in the local network (LAN, WLAN). The conversion also helps when wiring to the device you want to measure is too complicated. In that case you place the Reduxi Gateway near the device, connect it via RS485 and let it communicate with the Reduxi Controller via TCP/IP.
Current sensors. With current sensors, Reduxi Gateway works as a meter. It measures the energy consumption of the measured device when you clamp the sensors around the phase lines of the device. It measures the current flow as an absolute value, without the flow direction. It uses 230 V as the default voltage, or it takes the voltage per phase from one of the devices connected to the Reduxi Controller that provides voltage measurements.
Relay outputs. Through the relay outputs, Reduxi Gateway controls devices that support ON/OFF regulation. It can switch them off or on. One use case is a Smart Grid or EVU contact, where you control heat pumps by decreasing or increasing their consumption. You can use it for other applications with basic ON/OFF regulation too.
The user manual is available here: Reduxi Gateway manual
1.1 Indication lights of Reduxi Gateway
The indication lights give a quick overview of the operating state of Reduxi Gateway. Meaning of each light:
| Light | Colour and state | Meaning |
|---|---|---|
| LED 1 | Green | Power supply ON |
| LED 1 | Blue | Connected to the internet |
| LED 1 | Red | Error |
| LED 1 | White | Update/reset |
| LED 2 | Green, blinking | Reading on PORT 1 |
| LED 2 | Blue, blinking | Writing on PORT 1 |
| LED 3 | Green, blinking | Reading on PORT 2 |
| LED 3 | Blue, blinking | Writing on PORT 2 |
| LED 3 | Yellow | Modbus communication |
| LED 4 | Green | Relay 1 ON |
| LED 4 | Blue | Relay 2 ON |
| LED 4 | Turquoise | Relay 1 and relay 2 ON |
2 First connection to Reduxi Gateway
Reduxi Gateway offers two connection options. You connect it with an Ethernet cable directly to the network (LAN), or you connect to the access point of the Reduxi Gateway.
2.1 Wired connection
Connect Reduxi Gateway physically to the local network (LAN), to a switch or router. First make sure that Reduxi Gateway is plugged into the power supply included in the delivery package.
Once it is connected to the LAN, the Reduxi Gateway Configurator should open automatically ("popup") in your default browser. If it does not, follow the instructions in Point 3, section 3.1 Sign in to the Reduxi Gateway Configurator.
Symbolic picture of the Reduxi Gateway connection to a switch or router:
Text description of this image
Diagram with a drawing of the Reduxi Gateway connected to a switch or router, on a white background. Left: dark grey box-shaped device labelled Reduxi Gateway above it; the lid shows the reduxi GATEWAY logo. The front panel has printed labels: PWR (round power socket), ETH (RJ45 Ethernet port with a cable plug inserted), four small status LEDs, SW1 and SW2 (two-pin terminal blocks). Right: a router icon with Wi-Fi symbol and three dots, labelled Switch or router. A turquoise line leads from the ETH port of the gateway to the bottom of the router icon.
2.2 Wireless connection
To connect to the Wi‑Fi access point of the Reduxi Gateway, check the available Wi‑Fi networks on your smartphone or computer.
Once you are connected to the Wi‑Fi, the Reduxi Gateway Configurator should open automatically ("popup") in your default browser. If it does not, follow the instructions in Point 3, section 3.1 Sign in to the Reduxi Gateway Configurator.
Text description of this image
Screenshot of the Wi-Fi settings screen on a smartphone (iPhone-style Settings), tall image. Status bar: time 08:18, signal bars, 5G, battery 78. Header: back link Settings, title Wi-Fi, link Edit. First card: Wi-Fi toggle (green, on); below it a network named Gateway with a loading spinner on the left, a Wi-Fi signal icon and an info icon (i in a circle) on the right. Section heading NETWORKS with one entry: Other... Next card: Ask to Join Networks: Notify (with arrow). Grey help text: Known networks will be joined automatically. If no known networks are available, you will be notified of available networks. Next card: Auto-Join Hotspot: Ask to Join (with arrow). Grey help text: Allow this device to automatically discover nearby personal hotspots when no Wi-Fi network is available. The lower part of the screen is empty, with a black home indicator bar at the bottom.
3 Configure Reduxi Gateway
3.1 Sign in to the Reduxi Gateway Configurator
Once you are connected to the Wi‑Fi or the LAN, the configurator should open automatically ("popup") in your default browser. If it does not, enter this URL in the browser: http://gateway.local
If the configurator is still unreachable, check your internet connection. Check that you are connected to the same LAN or WLAN as the Reduxi Gateway.
Log in with these parameters:
- Username:
admin - Password:
admin
Text description of this image
Screenshot of the sign-in page of the Reduxi Gateway Configurator. Top: logo reduxi CONFIGURATOR. Background: light grey line drawing of a house roof with turquoise solar panels and a wall-mounted battery. Sign-in box with heading Sign-in; Username: empty field; Password: empty field; dark Login button. Under the box two small flag icons: United Kingdom flag and Slovenian flag, for language selection.
3.2 Configure network settings for a wired network connection
DHCP is the default protocol for assigning the IP address of Reduxi Gateway. We strongly recommend setting a static IP address. Go to Network settings / Wired network, set the protocol to STATIC and set the other parameters:
- IP address: set the IP address.
- Netmask: set the netmask (usually
255.255.255.0). - Gateway: set your network gateway (if needed).
- Primary DNS: set your DNS (if needed).
- Secondary DNS: set your DNS (if needed).
- Click the Save button under the network settings.
Text description of this image
Screenshot of the Network page of the Reduxi Gateway Configurator, wired network settings. Top: logo reduxi CONFIGURATOR on a light background with faint grey line drawings. Tabs: Home, Network (selected, dark), Serial, MQTT, System. Sub-tabs: Wired network (selected, bold) and Wireless network. Info line: C0:49:EF:08:6B:77 | 192.168.1.201. Fields: Protocol: STATIC; IP address: empty (red border with a red exclamation mark); Netmask: 255.255.255.0; Gateway: empty (red border with a red exclamation mark); Primary DNS: 8.8.8.8 (field focused, text cursor visible); Secondary DNS: 8.8.4.4. Dark save button with a disk icon at the bottom right. Below the box two small flag icons: United Kingdom and Slovenia.
3.3 Configure network settings for a wireless network
First fill in the information about the local Wi‑Fi that you choose as the preferred WLAN. Scan for the available Wi‑Fi networks with the Wi‑Fi icon on the right. Select your network, enter the password and connect.
DHCP is the default protocol for assigning the IP address of Reduxi Gateway. We strongly recommend setting a static IP address. Go to Network settings / Wireless network, set the protocol to STATIC and set the other parameters:
- IP address: set the IP address.
- Netmask: set the netmask (usually
255.255.255.0). - Gateway: set your network gateway (if needed).
- Primary DNS: set your DNS (if needed).
- Secondary DNS: set your DNS (if needed).
- Click the Save button under the network settings.
Text description of this image
Screenshot of the wireless network settings in the Reduxi Gateway Configurator. Top tabs: Home, Network (selected, dark), Serial, MQTT, System. Under it two links: Wired network, Wireless network (bold, selected). A red message box says: Wireless network is disabled by wired network. Pull out ethernet cable to continue. Fields from top to bottom: Wi-Fi SSID: empty, with a Wi-Fi icon button at its right; Password: empty; Protocol: STATIC; IP address: empty, red border with a red exclamation icon; Netmask: empty, red border with a red exclamation icon; Gateway: empty, red border with a red exclamation icon; Primary DNS: empty; Secondary DNS: empty. At the bottom right is a dark save button with a floppy disk icon.
3.4 Home page of the Reduxi Gateway
After you enter the Reduxi Gateway Configurator, the home page opens. It shows the currents, the voltages and the power of the measured device. The voltage data is transferred from the Reduxi Controller.
Text description of this image
Screenshot of the Home page of the Reduxi Gateway Configurator. Top: logo reduxi CONFIGURATOR on a light background with faint grey line drawings. Tabs: Home (selected, dark), Network, Serial, MQTT, System. Heading: Gateway. Rows with value and timestamp 4. 6. 2024 09:25:46 each: Current L1: 0.00 A; Current L2: 0.00 A; Current L3: 0.00 A; Relay 1: OFF; Relay 2: OFF; Voltage L1: 230.00 V; Voltage L2: 230.00 V; Voltage L3: 230.00 V; Power: 0.00 kW. Footer text: Firmware version: Thu May 30 13:11:15 2024.
3.5 Reduxi Gateway serial port settings
If you use the RS485 ports for the serial connection, set these parameters:
- Baud rate: set the baud rate.
- Data bits: set the number of data bits.
- Stop bits: set the number of stop bits.
- Parity: choose the parity.
- After all serial settings, click the Save button at the bottom right.
Text description of this image
Screenshot of the Serial page of the Reduxi Gateway Configurator. Top: logo reduxi CONFIGURATOR on a light background with faint grey line drawings. Tabs: Home, Network, Serial (selected, dark), MQTT, System. Sub-tabs: PORT 1 (selected, bold) and PORT 2. Fields: Baud rate: 38400 bits/s; Data bits: 8; Stop bits: 1; Parity: None. Dark save button with a disk icon at the bottom right.
3.6 Reduxi Gateway MQTT settings
Reduxi Gateway can be configured and read via the MQTT broker to which it connects. For successful communication with the broker, fill in this information:
- Enable MQTT: Yes/No. Select Yes.
- Host: enter the URL where the broker is located.
- Username and password: enter the username and password used to log in to the broker URL.
- Use SSL: select it if SSL is used.
- Verify server cert: select it if you use a server certificate.
- Server CA chain (PEM format): select the server certificate file.
- Client private key (PEM format): select the server certificate file.
- Client public key (PEM format): select the public key file.
- After all MQTT settings, click the Save button at the bottom right.
Text description of this image
Screenshot of the MQTT page of the Reduxi Gateway Configurator. Top: logo reduxi CONFIGURATOR on a light background with faint grey line drawings. Tabs: Home, Network, Serial, MQTT (selected, dark), System. Fields: Enable MQTT: Yes (on); Host: hidden by a black-framed white box; Username: hidden by a black-framed white box; Password: four dots, shown with a grey highlight; Use SSL: No (off); Verify server cert: No (off); Server CA chain (PEM format): file picker with button Izberite datoteko [Choose file] and text Nobe.rana [No file selected, cut off]; Client public certificate (PEM format): file picker, Izberite datoteko, Nobe.rana; Client private key (PEM format): file picker, Izberite datoteko, Nobe.rana. Dark save button with a disk icon at the bottom right.
Instructions for using the MQTT broker: MQTT instructions
3.7 Reduxi Gateway system settings
The system settings contain these options:
- Username: cannot be changed.
- Password: enter a new password.
- Password confirmation: enter the new password again.
- Current 1/2/3: set the current ratio of the current sensor.
- Relay 1/2 - default: specify the default position of the relay.
- Enable Modbus TCP/IP: enable it if you read on the RS-485 inputs.
- After all system settings, click the Save button at the bottom right.
Text description of this image
Screenshot of the System page of the Reduxi Gateway Configurator. Top: logo reduxi CONFIGURATOR on a light background with faint grey line drawings. Tabs: Home, Network, Serial, MQTT, System (selected, dark). Fields: Username: admin (greyed, read-only look); Password: empty; password_confirmation: empty; Current tr. 1: 0 A; Current tr. 2: 0 A; Current tr. 3: 0 A; Relay 1 - default: Off (toggle); Relay 2 - default: Off (toggle); Enable Modbus TCP/IP: Yes (toggle on). Dark save button with a disk icon at the bottom right. Below on the left four square icon buttons without text: a cloud with a download arrow, a circular arrow, a circle with an arrow and a clock-like symbol, and a red button with an exit arrow.
4 Add Reduxi Gateway to the Reduxi Controller
4.1 Ping test between Reduxi Controller and Reduxi Gateway in the same network
When the Reduxi Controller and the Reduxi Gateway are connected to the same network (LAN, WLAN), run a ping test. It shows that the Reduxi Controller can reach the Reduxi Gateway.
Log in to the Reduxi Configurator and click the Setting button at the bottom left of the home page.
Text description of this image
Screenshot of the left menu of the Reduxi Configurator, tall image. Top: logo reduxi CONFIGURATOR. Entries: Devices (bold, white, plus sign); Strategies (plus sign); then an empty grey area. Lower part: two buttons side by side, + Add device and + Add strategy; below them the entry Settings, marked with a blue rectangle; below it the entry Profile.
The ping test needs three clicks:
Text description of this image
Screenshot of the left menu of the Reduxi Configurator. At the top is the reduxi logo with the word CONFIGURATOR under it. Menu entries from top to bottom, each in its own row: Users, Devices, Strategies, System. A blue square with a black plus sign is at the right end of the System row. The rest of the screenshot to the right of the menu is white and empty.
Text description of this image
Screenshot of the left settings menu of the Reduxi Gateway Configurator. Logo: reduxi CONFIGURATOR. Menu entries from top: Users; Devices; Strategies; System (expanded, minus sign, white background); under System: Identifier; Basic settings; Network; Open VPN; Connector (plus sign); Configuration (plus sign); Distribution System Operators; Time; Patch; Reboot; Factory reset; Tools (plus sign, marked with a blue square at the bottom right of the menu).
Text description of this image
Screenshot of the left settings menu of the Reduxi Gateway Configurator, tall image. Logo: reduxi CONFIGURATOR. Entries from top: Users; Devices; Strategies; System (expanded, minus sign, white background); under System: Identifier; Basic settings; Network; Open VPN; Connector (plus sign); Configuration (plus sign); Distribution System Operators; Time; Patch; Reboot; Factory reset; Tools (expanded, minus sign); under Tools: Ping test (marked with a blue rectangle) and TCP port test.
Enter the IP address of the Reduxi Gateway and click the Test button. You can use an IP address or the DNS name gateway.local.
The ping test has two possible results:
Text description of this image
Screenshot of the Ping test tool in the Reduxi Gateway Configurator. Section title: Ping test. Host: 192.168.1.121. Result box with this text: PING 192.168.1.121 (192.168.1.121) 56(84) bytes of data. / 64 bytes from 192.168.1.121: icmp_seq=1 ttl=64 time=1.04 ms / 64 bytes from 192.168.1.121: icmp_seq=2 ttl=64 time=0.722 ms / --- 192.168.1.121 ping statistics --- / 2 packets transmitted, 2 received, 0% packet loss, time 501ms / rtt min/avg/max/mdev = 0.722/0.881/1.040/0.159 ms. The ping was successful.
Text description of this image
Screenshot of the Ping test tool in the Reduxi Gateway Configurator. Section title: Ping test. Host: 192.168.1.122. Result box with this text: PING 192.168.1.122 (192.168.1.122) 56(84) bytes of data. / --- 192.168.1.122 ping statistics --- / 2 packets transmitted, 0 received, 100% packet loss, time 508ms. The ping failed, no reply lines are shown.
4.2 Reduxi Gateway as Reduxi meter
An example of how to add a Reduxi Gateway as a Reduxi meter: Kronoterm Heat pump with SG ready contacts. In this example the Reduxi Gateway serves as the energy meter for the heat pump. Configure the relays of the Reduxi Gateway as described in the example.
Symbolic image from the example:
Text description of this image
Diagram of the connection between the Reduxi Controller and a heat pump. Components: Controller (dark Reduxi box with a green display and an Ethernet port on its front); a router icon with Wi-Fi symbol; Heat pump (outdoor unit with fan and an SG Ready badge at its left); Gateway (Reduxi Gateway box with three blue current sensors attached). Teal lines: Controller to router labelled "Ethernet (Modbus TCP)"; router to Gateway labelled "Ethernet (Modbus TCP)" with the note "Wireless or wired" under the router; Gateway to the SG Ready contacts of the heat pump (line from the Gateway up to the SG Ready badge); a vertical line from the Gateway to the heat pump labelled "L1, L2, L3"; a line from the current sensors to a teal box "Heat pump power supply".
Modbus settings from the example for the Reduxi meter:
Text description of this image
Screenshot of the Reduxi Configurator add-device wizard, communication step, partly cropped at the top (step tabs cut off). Heading: Communication channel and device configuration. Fields: Connection *: TCP-IP; IP *: gateway.local; Port *: 502; Modbus unit ID *: 1. The image is cut off below the Modbus unit ID field.
Current sensor and relay output settings from the example for the Reduxi meter:
Text description of this image
Screenshot of a settings form in the Reduxi Gateway Configurator with current transformer and relay settings. All fields are dropdowns; required fields are marked with an asterisk. Fields as Label: value (grey hint text under the field): CT- L1 *: 30 A (Current transformer); CT- L2 *: 30 A (Current transformer); CT- L3 *: 30 A (Current transformer); Off - relay 1: Off (Setpoint of the relay 1 when heat pump setpoint is off); Off - relay 2: On (Setpoint of the relay 2 when heat pump setpoint is off); ECO - relay 1: Off (Setpoint of the relay 1 when heat pump setpoint is ECO); ECO - relay 2: On (Setpoint of the relay 2 when heat pump setpoint is ECO); ON - relay 1: Off (Setpoint of the relay 1 when heat pump setpoint is ON); ON - relay 2: Off (Setpoint of the relay 2 when heat pump setpoint is ON); BOOST - relay 1: On (Setpoint of the relay 1 when heat pump setpoint is BOOST); BOOST - relay 2: Off (Setpoint of the relay 2 when heat pump setpoint is BOOST).
4.3 Reduxi Gateway for use of RS485
In contrast to point 4.2, you can use Reduxi Gateway as an add-on device to the Reduxi Controller, placed in another location. Then you need to establish a connection between the controller and the gateway (see Point 4, section 4.1 Ping test).
An example of Reduxi Gateway with RS485 for the connection to a smart meter Iskraemeco AM550: Connect to Smart meter Iskraemeco AM550
Symbolic image from the example:
Text description of this image
Diagram of the connection from the Reduxi Controller to a smart meter via the Reduxi Gateway and RS485, on a white background. Components: black Reduxi Controller (label Reduxi Controller) with a blue-framed RJ45 port and a green two-terminal block; Reduxi Gateway (label Reduxi Gateway), a dark grey box with a six-pin terminal block and three blue current clamps plugged into I1, I2 and I3; a router icon with Wi-Fi symbol; a small black converter labelled Reduxi Converter; a grey smart meter labelled Smart meter Iskraemeco AM550. Connections (turquoise lines): from the RJ45 port of the controller down and right to the router, labelled Modbus TCP/IP connection, Wired or wireless; from the router up to the top of the gateway, labelled Modbus TCP/IP connection, Wired or wireless (vertical text); from the smart meter to the converter, no label; three wires (blue, orange, green) from the terminal block of the gateway to the three-pin connector of the converter, no labels.
Modbus settings from the example for Reduxi Gateway used with RS485:
Text description of this image
Screenshot of a device form in the Reduxi Configurator with two sections. Left section Communication channel: Connection *: Gateway (dropdown); IP *: 192.168.1.121 (field focused, text cursor visible, light blue background); Port *: Port 1 (dropdown); Baud rate *: 38400 bits/s (dropdown); Data bits *: 8 (dropdown); Stop bits *: 1 (dropdown); Parity *: None (dropdown). Right section Device configuration: Interface type *: HDLC (dropdown); Block cipher key: empty; Authentication key: empty; Message structure *: Standard Reduxi telegram for Iskraemeco AM550 (dropdown). Asterisks mark required fields.
After you have added the device and checked the values, you can inspect and control the device in the Reduxi application.
✓ Summary
Introduction (Point 1): Reduxi Gateway measures with current sensors, switches devices through relay outputs and converts RS485 to TCP/IP. The indication lights show its state.
Connect (Point 2): Connect the Gateway to the LAN with an Ethernet cable or to its Wi‑Fi access point GATEWAY.
Configure (Point 3): Open gateway.local, log in, set a static IP address, then set serial port, MQTT and system settings as needed.
Add to Reduxi (Point 4): Run the ping test from the Reduxi Configurator, then add the Gateway as Reduxi meter or for RS485 use.
→ Common issues
| Issue | Solution |
|---|---|
| The configurator does not open automatically | Enter http://gateway.local in the browser. Check that you are connected to the same LAN or WLAN as the Reduxi Gateway (see Point 3). |
| The Reduxi Gateway is not reachable from the Reduxi Controller | Run the ping test with the IP address or gateway.local (see Point 4). Both devices must be in the same network. |
| No values from the RS-485 inputs | Enable Modbus TCP/IP in the system settings and click Save (see Point 3). |